  • Floor joists- 2 x 10 @ 16” O.C. SPF #2 or better with double perimeter band all widths.
    (except for 31’-6”widths will be 12” O.C.)
    All floors constructed with solid wood bridging.

  • 3/4” T&G OSB floor decking, glued and nailed

  • Floor coverings on site by others, except
    kitchen, bath, utility and laundry areas will
    feature 16 ” x 16 ” Elements vinyl tile installed.

 
  • Therma-Tru Smooth Star fiberglass 6-panel front door with knocker & peep
  • Therma-Tru Smooth Star fiberglass 9-lite rear door (keyed alike with front door)
  • SilverLine double hung vinyl windows with full screen, GBG (grills between the glass), LoEČ glass, colonial profile, and integral siding channel.
  • Brushed nickel exterior light fixtures at all exterior doors
  • Wireless door bell @ front and rear doors
 
  • Premium grade (.46 gauge) vinyl siding in traditional 4/4 or 5/5 lap profile
  • Aluminum fascia
  • Vented vinyl soffit on eaves, non-vented on gables
  • Panel shutters on front elevation
 
  • Merillat Seneca Ridge Oak raised panel cabinetry
  • CM Crown molding over kitchen cabinets
  • Roll-out shelves in base cabinets
  • Beveled edge high pressure laminate countertop with backsplash
 
  • Lasco brand bath fixtures - 1-pc. tub/shower per plan
  • Delta brand faucets in Brilliance Stainless Finish
  • Beveled edge plate mirror at vanity w/brushed nickel light
  • Merrillat Seneca Ridge Oak raised panel vanity base drawer cabinet - Cultured marble vanity top with single bowl
  • Cultured marble vanity top with single bowl
  • Elongated china water closet
 
  • Exterior walls 2 x 6 @ 16" O.C. with 7/16" OSB sheathing Solid headers with OSB reinforcement
  • Interior walls 2 x 4 @ 16" O.C.
  • 8' Ceiling height
  • Mating walls 2 x 4 @ 16" O.C. with 7/16" OSB reinforcement.
  • Smooth finish interior walls with 2-coats of primer applied
 
  • 7/12 Hinged rafter roof system @ 16" O.C. (Gable end walls and porches to match roof spacing) Attic floor decking 5/8” T&G OSB
  • 7/16" OSB roof sheathing
  • #15 underlayment paper
  • Ice guard at eaves
  • 30 year Owens Corning Architectural shingles
  • 10" eave overhangs - hinged on homes wider than 26'
  • 10" gable end overhangs
  • Aluminum drip-edge
  • 5/8" Type X drywall on celings with smooth finish
  • Access panel to rafter area standard, optional pull-downstairs and  fixed stairs also available
 
  • 200 AMP circuit panel w/ 40 breaker capacity
  • Silent Rocker style switches
  • GFI circuits per code
  • A/C-D/C Smoke detectors per code
  • Switched bedroom receptacle
  • Ceiling fan/light combination all baths
  • ALLURE range hood
  • Ceiling lights in basement stairwell, attic, walk-in closets, brushed nickel ceiling lights in hall, open foyer, laundry, kitchen, breakfast nook, and dining room.
  • 2ea CAT5 phone and 2ea RG6 TV jacks
 
  • White 6-panel colonial doors w/ 3 mortised hinges

  • Colonial trim - (2 1/2" doors & windows) - (3 1/2" base) pre-finished white or light medium stain

  • Window sills through-out

  • Brushed nickel passage & privacy interior door knobs and hinges

 
  • Copper water supply lines stubbed through floor *per available upon request
  • PVC drain, waste and vent lines
  • Shut-off valves on all fixtures
  • Anti-scald valves on all tubs and showers
  • Leland series Delta faucets in Brilliance Stainless finish
  • Delta Single lever kitchen faucet with pull-down spray
  • 8" deep bowl stainless steel sink in kitchen w/ spray
  • 50 gallon electric water heater - shipped loose
  • R-19 Kraft-faced fiberglass in exterior walls
  • Wind/House wrap
  • R-30 Kraft-faced fiberglass in ceiling
 
  • None: various options available
     
Additional Design Specifications CAPE   Additional Design Specifications TWO-STORY
  • 12/12 @ 16" O.C. hinged rafter roof system

  • Stairs to second floor installed - oak tread/pine riser (railing optional) * other stair tread/riser and railing optional available

  • Close-off package - one 30" door, trim, 24' of wall material (2 x 4 studs and drywall) shipped loose for completion by the builder in the field

  • 5/8" OSB floor decking second floor between the knee-walls

  • Plumbing and electric supply stubbed to second floor for future use

  • 2 gable-end windows shipped loose

 
  • 2 x 6 @ 16" O.C. ceiling joists with double 2 x 10 perimeter band

  • Fiberglass insulation around exterior perimeter between floors and ceilings - 2' back from the perimeter

  • 28 x 56 window sizing on first floor except for kitchen and baths

  • All second story siding shipped loose

  • Stairs to second floor installed - oak tread/pine risers (railing optional) *other stair tread/riser and railing options available

  • Plumbing and electrical chase included

SITE-BUILT ATTACHMENTS:

Many exterior attachments as shown on the elevations are materials required to be supplied locally or installed by others at the job site. Such items include: Porches, garages, dormers or gables, sky lights, and other items which may be prohibited from being plant-installed due to shipping restraints or shop limitations.

 

Many Additional Options Are Available - See Your Authorized CBS Builder

 

See your CBS Builder to select the options you desire and to verify standard specifications. The information provided here may change without notice and without incurring any obligation due to continuous product improvements. Some items shown may be optional. Floor plans are promotional illustrations that approximate size and may depict optional or suggested features that are site-attachments built by others.

Updated 10/1/2007

 
 