Floor joists- 2 x 10 @ 16”
O.C. SPF #2 or better with double perimeter band all
widths.
(except for 31’-6”widths will be 12” O.C.)
All floors constructed with solid wood bridging.
-
3/4” T&G OSB floor decking, glued and nailed
-
Floor coverings on site by others, except
kitchen, bath, utility and laundry areas will
feature 16 ” x 16 ” Elements vinyl tile installed.
|
|
- Therma-Tru Smooth Star fiberglass
6-panel front door with knocker & peep
- Therma-Tru Smooth Star fiberglass
9-lite rear door (keyed alike with front door)
- SilverLine double hung vinyl windows
with full screen, GBG (grills between the glass), LoEČ
glass, colonial profile, and integral siding channel.
- Brushed nickel exterior light
fixtures at all exterior doors
- Wireless door bell @ front and rear
doors
|
 |
|
 |
- Premium grade (.46 gauge) vinyl
siding in traditional 4/4 or 5/5 lap profile
- Aluminum fascia
- Vented vinyl soffit on eaves,
non-vented on gables
- Panel shutters on front
elevation
|
|
- Merillat Seneca Ridge Oak raised
panel cabinetry
- CM Crown molding over kitchen
cabinets
- Roll-out shelves in base cabinets
- Beveled edge high pressure laminate
countertop with backsplash
|
 |
|
 |
- Lasco brand bath fixtures - 1-pc.
tub/shower per plan
- Delta brand faucets in Brilliance
Stainless Finish
- Beveled edge plate mirror at vanity
w/brushed nickel light
- Merrillat Seneca Ridge Oak raised
panel vanity base drawer cabinet - Cultured marble
vanity top with single bowl
- Cultured marble vanity top with single bowl
- Elongated china water closet
|
|
- Exterior walls 2 x 6 @ 16" O.C. with
7/16" OSB sheathing Solid headers with OSB reinforcement
- Interior walls 2 x 4 @ 16" O.C.
- 8' Ceiling height
- Mating walls 2 x 4 @ 16" O.C. with
7/16" OSB reinforcement.
- Smooth finish interior walls with
2-coats of primer applied
|
 |
|
 |
- 7/12 Hinged rafter roof system @ 16"
O.C. (Gable end walls and porches to match roof spacing)
Attic floor decking 5/8” T&G OSB
- 7/16" OSB roof sheathing
- #15 underlayment paper
- Ice guard at eaves
- 30 year Owens Corning Architectural
shingles
- 10" eave overhangs - hinged on homes
wider than 26'
- 10" gable end overhangs
- Aluminum drip-edge
- 5/8" Type X drywall on celings with
smooth finish
- Access panel to rafter area standard,
optional pull-downstairs and fixed stairs also
available
|
|
- 200 AMP circuit panel w/ 40 breaker
capacity
- Silent Rocker style switches
- GFI circuits per code
- A/C-D/C Smoke detectors per code
- Switched bedroom receptacle
- Ceiling fan/light combination all
baths
- ALLURE range hood
- Ceiling lights in basement
stairwell, attic, walk-in closets, brushed nickel
ceiling lights in hall, open foyer, laundry, kitchen,
breakfast nook, and dining room.
- 2ea CAT5 phone and 2ea RG6 TV jacks
|
 |
|
 |
-
White 6-panel colonial doors w/ 3
mortised hinges
-
Colonial trim - (2 1/2" doors &
windows) - (3 1/2" base) pre-finished white or light
medium stain
-
Window sills through-out
-
Brushed nickel passage & privacy
interior door knobs and hinges
|
|
- Copper water supply lines stubbed
through floor *per available upon request
- PVC drain, waste and vent lines
- Shut-off valves on all fixtures
- Anti-scald valves on all tubs and
showers
- Leland series Delta faucets in
Brilliance Stainless finish
- Delta Single lever kitchen faucet
with pull-down spray
- 8" deep bowl stainless steel sink in
kitchen w/ spray
- 50 gallon electric water heater -
shipped loose
|
 |
 |
- R-19
Kraft-faced fiberglass in exterior walls
- Wind/House
wrap
- R-30
Kraft-faced fiberglass in ceiling
|
|
- None:
various options available
|
| |
|
|
| Additional Design
Specifications CAPE |
|
Additional Design Specifications TWO-STORY |
-
12/12 @ 16" O.C. hinged
rafter roof system
-
Stairs to second floor
installed - oak tread/pine riser (railing optional)
* other stair tread/riser and railing optional
available
-
Close-off package - one
30" door, trim, 24' of wall material (2 x 4 studs
and drywall) shipped loose for completion by the
builder in the field
-
5/8" OSB floor decking
second floor between the knee-walls
-
Plumbing and electric
supply stubbed to second floor for future use
-
2 gable-end windows
shipped loose
|
|
-
2 x 6 @ 16" O.C. ceiling joists with
double 2 x 10 perimeter band
-
Fiberglass insulation around
exterior perimeter between floors and ceilings - 2'
back from the perimeter
-
28 x 56 window sizing on first floor
except for kitchen and baths
-
All second story siding shipped
loose
-
Stairs to second floor installed -
oak tread/pine risers (railing optional) *other
stair tread/riser and railing options available
-
Plumbing and electrical chase
included
|
|
SITE-BUILT ATTACHMENTS: |
|
Many exterior attachments as
shown on the elevations are materials required to be
supplied locally or installed by others at the job site.
Such items include: Porches, garages, dormers or gables, sky
lights, and other items which may be prohibited from being
plant-installed due to shipping restraints or shop
limitations. |
| |
|
Many Additional Options
Are Available - See Your Authorized CBS Builder |
| |
|
See your CBS Builder to
select the options you desire and to verify standard
specifications. The information provided here may change
without notice and without incurring any obligation due to
continuous product improvements. Some items shown may be
optional. Floor plans are
promotional illustrations that approximate size and may
depict optional or suggested features that are
site-attachments built by others. |